MI L-DTL-53133/ 5B
DRAWI NGS
TA 30554-88-804
- Generator Set, Tactical, Quiet, 15 kW, 50/ 60 Hz.
(Copies of drawings required by contractors in connection with specific acquisition
functions should be obtained from the US Army Communications-Electronics Command,
ATTN: AMSEL-LC-ED-BG, 10115 Gridley Road, Ste 201, Fort Belvoir, VA 22060-5849.)
3. REQUI REMENTS
3.1 Requirements. Requirements for acquiring the product described herein shall
consist of this document and MI L-DTL-53133.
3.2 Description. The set shall be in accordance with TA 30554-88-804 and as
specified herein.
3.3 Reliability. The minimum acceptable mean time between failure (MTBF for the
set shall be 538 hours with a 80 percent lower confidence limit.
3.4 Size and weight. The maximum operating set dimensions with control panel
doors closed and the total operational weight shall not exceed the following:
Parameter
Dimension
1760 mm (69.3 inches)
Length
897 mm (35.3 inches)
Width
1374 mm (54.1 inches)
Height
963.4 kg (2124 pounds)
Weight
3.5 Fuel consumption. Fuel consumption, at all loads up to and including rated load,
shall not be more than 5.69 l/ h (1.50 gallons per hour [ GPH] ) when the set is operating
on referee grade diesel fuel conforming to MI L-F-46162.
3.6 Parallel operation. With their governor and voltage regulator paralleling circuits
interconnected, two sets of the same mode and size operated in parallel shall divide
load in accordance with the following as system load (at rated power factor) is varied
between zero and 100 percent (and vice versa) of the combined rating of the connected
sets:
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business