INCH-POUND
MIL-DTL-62186C
06 August 2009
SUPERSEDING
MIL-DTL-62186B
6 January 1999
DETAIL SPECIFICATION
GENERATOR, ALTERNATING CURRENT (650 AMPERE RECTIFIED),
28 VOLTS DIRECT CURRENT (OIL COOLED)
This specification is approved for use by all Departments and Agencies of the
Department of Defense.
1. SCOPE
1.1 Scope. This specification defines the requirements for an alternating current,
650 ampere rectified, 28 volt direct current, oil cooled generator, referred to herein as
"alternator," used in the electrical generating systems of the M60 series tanks (see 6.1).
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this
specification. This section does not include documents in other sections of this specification or
recommended for additional information or as examples. While every effort has been made to
ensure the completeness of this list, document users are cautioned that they must meet all
specified requirement documents cited in sections 3 and 4 of this specification, whether or not
they are listed.
Comments, suggestions, or questions on this document should be addressed to U.S. Army
Tank-automotive and Armaments Command, ATTN: RDTA-EN/DM/STND, MS# 268, 6501 E.
11 Mile Road, Warren, MI 48397-5000 or emailed to
DAMI_STANDARDIZATION@conus.army.mil. Since contact information can change, you
may want to verify the currency of this address information using the ASSIST Online database at
https://assist.daps.dla.mil.
AMSC N/A
FSC 6115
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744